Tuesday, November 21, 2017

  

J&B Lock and Alarm Inc

272 Closter Dock Rd , Closter NJ 07624
201.767.0999
427 Boulevard , Hasbrouck Heights NJ 07604
201.288.8823

Vista 128BP 128 Zone Control Panel

 

Commercial Burglary/CCTV and Access Control Platform

The new VISTA-128BP is an eight partition, 128 zone UL commercial burglary control panel that meets the demanding requirements of today’s commercial installations while simplifying end-user operation.

A revolutionary new feature called Panel Linking allows multiple partitions, panels—even buildings—to be armed, disarmed and have status checked all from one location. Up to eight VISTA-128BP panels can be linked together, and the control can be integrated with ADEMCO’s PassPoint system (via the VISTA Gateway Module) to provide a fully integrated security and access control system. The VistaKey Access Control system and the VistaView-100 CCTV Switcher can also be seamlessly integrated with this powerful commercial platform.

 

Owners Manual               Keypads for this System

Features

 

  • Provides nine style-B hardwired zones
  • Supports up to 119 additional zones using a built-in polling (multiplex) loop interface
  • Supports up to 128 wireless zones using 5881 type RF receiver (fewer if using hardwired and/or polling loop zones)
  • Provides one power-limited bell circuit delivering 1.7Amp (max) at 12Vdc.
  • Provides the ability to control eight separate partitions independently, each functioning as if it had its own separate control
  • Accommodates 150 user codes with seven authority levels
  • Accommodates 32 keypad macro commands per system
  • Keeps a log of up to 512 events
  • VistaView-100 CCTV support
  • Supports up to 16 two-wire smoke detectors on zone 1
  • Supports up to 50 latching-type glassbreak detectors on zone 8
  • Zone 7 may be used for keyswitch arming/disarming
  • Integrates with PassPoint access control systems to provide increased users, event log, and scheduling (up to 32 doors)
  • Supports V-Plex addressable VistaKey access control (up to eight doors and 250 cards)
  • Easily programmed and maintained by the newly upgraded Compass Windows-based downloader
  • Supports up to 96 programmable relays
  • Supports the ADEMCO 4286 VIP Module
  • False alarm reduction features

     

New Enhancement:

  • Two-Way RS232 (facility automation software support) optional
  • Supports eight numeric pager numbers
  • Supports touch screen Advanced User Interface (AUI) (Future)
  • Smoke Detector Reset at keypad
  • QUICK EXIT
  • Group Bypass
  • Arm Faulted
  • Event Arming
  • Scheduled check-in
  • ARM STAY by group

Additional Features
Basic Hardwired Zones
Provides nine style-B hardwired zones with the following characteristics:

  • EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations)
  • Individually assignable to one of eight partitions
  • Up to 16 two-wire smoke detectors on zone 1
  • Four-wire smoke or heat detectors on zones 1-8 (power to four-wire smoke detectors must be supervised with an EOL device)
  • Up to 50 two-wire latching glassbreak detectors on zone 8

Polling Loop Expansion
Supports up to 119 additional zones using a built-in polling (multiplex) loop interface. Current draw can total up to 128mA. Polling loop zones have the following characteristics:

  • Must use RPM (Remote Point Module) devices
  • Supervised by control panel
  • Individually assignable to one of eight partitions

Wireless Expansion

Supports up to 128 wireless zones using 5881 RF receiver (fewer if using hardwire and/or polling loop zones). Wireless zones have the following characteristics:

  • Supervised by control panel for check-in signals (except certain non-supervised transmitters)
  • Tamper protection for supervised transmitters
  • Individually assignable to one of eight partitions

Scheduling

Provides the following scheduling capabilities:

  • Open/close schedules (for control of arming/disarming and reporting)
  • Holiday schedules (allows different time windows for open/close schedules)
  • Timed events (for activation of relays, auto-bypassing and unbypassing, auto-arming and disarming, etc.)
  • Access schedules (for limiting system access to users by time)
  • End user output programming mode (provides 20 timers for relay control)

Eight Partitions

Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control. Partitioning features include:

  • A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed and to disarm when the first partition that shares the common lobby is disarmed
  • A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads)
  • All zones assignable to one of eight partitions
  • Keypads assignable to one of eight partitions or to master partition 9 to view system status
  • Ability to assign relays to one or all eight partitions
  • Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions' keypads (selectable option)
  • Certain system options selectable for each partition, such as entry/exit delay and subscriber account number

New Enhancement

  • allows multiple control panels to be networked together and controlled from any keypad in the system:
  • Control multiple zones, partitions, buildings from a central location
  • Check status, arm and disarm any partition from any keypad in the system (based on user’s authority level)
  • Users can have a different authority level in each partition and access to different partitions in each panel
  • Global Arming - users can arm and disarm all the partitions in all the panels they have access to, with one set of keystrokes

Applications

The VISTA-128BP control is well suited for a variety of applications as a burglary control and is supported by a diverse line of ADEMCO initiating devices. Applications include medical and professional buildings, supermarkets, churches or synagogues, office buildings, schools, universities, strip malls, larger residences and factory or warehouse environments.

Installation
The VISTA-128BP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL-Commercial Burglary installations, use the Vista-ULKT kit when an attack resistant enclosure is required.

Agency Listings Burglary

  • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault
  • UL611/UL1610 Grades A, AA Central Station
  • UL365 Grades A, AA Police Connect
  • UL985 Household Fire
  • California State Fire Marshall (CSFM)
  • UL listing 1023 - Household Burglar Alarm

     

 

 

 


Copyright 2008 by J & B Lock And Alarm Terms Of Use Privacy Statement